Our complete technical documentation library: product data sheets, R-value performance tables, fire test reports, installation guides, and specification details for architects and engineers.
All R-values measured per ASTM C518 and C177 at 75°F mean temperature unless otherwise noted. Long-term aged values provided for polyiso per ASTM C1289.
| Product Name | Nominal Thickness | R-Value | Test Standard | Document |
|---|---|---|---|---|
| ComfortTherm® R-13 Batt | 3.5 in | R-13 | ASTM C518 | Request PDF |
| ComfortTherm® R-15 Batt | 3.5 in | R-15 | ASTM C518 | Request PDF |
| ComfortTherm® R-19 Batt | 6.25 in | R-19 | ASTM C518 | Request PDF |
| ComfortTherm® R-30 Batt | 10 in | R-30 | ASTM C518 | Request PDF |
| Invinsa® Polyiso Board | 2 in | R-13.1 (aged) | ASTM C1289 | Request PDF |
| Invinsa® Polyiso Board | 3 in | R-19.6 (aged) | ASTM C1289 | Request PDF |
| Temp-Control® Mineral Wool | 1.5 in | R-6.0 @ 75°F | ASTM C177 | Request PDF |
Note: Published R-values assume correct installation per manufacturer's guidelines. Actual field performance may vary based on installation quality, moisture content, and air barrier integrity.
UL assembly numbers, fire test results, and STC/NRC acoustic performance data. All fire ratings applicable in US and Canada unless otherwise noted.
| Assembly / Product | Fire Rating | Test Standard | UL Number | Document |
|---|---|---|---|---|
| 2×6 Wood Frame Wall + R-21 Batt | 1-Hour | ASTM E119 | U301 | Request PDF |
| Metal Stud Wall + R-15 Batt | 2-Hour | ASTM E119 | U411 | Request PDF |
| Commercial Roof + Polyiso | Class A | ASTM E108 | R0001 | Request PDF |
| Mineral Wool Fire Barrier | 3-Hour | ASTM E119 | U411M | Request PDF |
Correct friction-fit technique, vapor retarder orientation, and air sealing best practices for walls, floors, and attics.
Request Guide →Step-by-step duct insulation wrapping procedure, stapling patterns, and FSK tape sealing requirements.
Request Guide →Pre-formed pipe section OD sizing for all standard pipe diameters and schedules, ASTM C547 compliance reference.
Request Chart →Complete specification guide for polyiso substrate preparation, membrane selection, and fastening pattern calculations.
Request Manual →Download AutoCAD .dwg, DXF, and Revit .rfa BIM object files for integration into your project documentation workflows.
Standard wood and metal stud wall sections with batt and CI insulation.
Download →Polyiso tapered roofing system sections with membrane attachment details.
Download →Revit families for ComfortTherm batts, pipe insulation, and duct liner.
Download →